Flygt – MAS 801 Pump Monitoring System

Enquire About This Product

  • Description

    Leading pump protection, overview and analysis

    MAS 801 is designed to further enhance the outstanding reliability of a Flygt pump with 24/7 on-site overview of pump data and continuous station health check, to detect failures before they can do damage. As part of a complete Flygt pumping system, MAS helps reduce costs over a pump’s lifetime. With three-axis vibration, current, temperature and leakage measurements to alarm of deviating values, the operator is able to take early and preventive measures. The “black-box” sensor data linking the alarm items with logged data, provides a unique fault tracing feature. Power and communication signals combined through a single cable and the pre-configured pump memory with individual alarm set-points and asset data, facilitates startup and maintenance. 

    Measuring and recording capability

    MAS 801 measures, records and monitors different values that can be plotted or exported:

    Standard monitoring 

    • Motor temperature 
    • Main bearing temperature 
    • Leakage monitoring in the stator housing and junction box 
    • Pump current in one phase 
    • Vibration in three-axis 
    • Running time & number of starts 

    Optional monitoring 

    • Motor temperature in three phases 
    • Support bearing temperature 
    • Water in oil detection 

    Optional power analyzer 

    • Pump current in three phases 
    • Current imbalance 
    • Voltage in three phases 
    • Voltage imbalance 
    • Power factor 
    • Power 
    • Energy (kW-hours)

    Flygt MAS 801 is suitable for 3000, 5000 & 7000 series pumps.

  • Suitability

    Monitoring Systems

  • Technical Features


    Product Features

    • Early warnings from changes in current, temperature, leakage and vibration to reduce premature shutdowns 
    • 10 separate warning parameters identify part wear and tear 
    • Color HMI touchscreen ranging from 7” to 15” with up to 10 pumps side-by-side for quick station overview 
    • Web tool with real-time access to pump data for easy handling, same great station overview and analysis from any device such as a tablet or phone 
    • Signal cable eliminated, using screened and twisted lead pairs SUBCAB cable 
    • Pump memory with factory set-points and pump id, simplifying installation and maintenance 
    • Extensive black box incident recording associated with alarms 
    • SCADA connectivity, openness and remote communication 
    • Root cause suggestions help troubleshoot failures for faster system restarts