Wilo-Sub TWI 5/TWI 5-SE

Multistage, submersible, rainwater storage tank pump.

Enquire About This Product

  • Description

    Wilo-Carus Air Super is the ideal solution to provide continuous air venting of closed heating and chilled water circuits in domestic and commercial buildings. The design with protective cap and the expansion sealer rings prevents leaks.

    The long distance between the water and the closing mechanism as well as the conical shape of the cap reduce the possibility of contamination.

  • Advantages
    • Higher efficiency of the heating and chilled water system thanks to the intelligent “open closed”- principle of the float valve
    • High reliability and less maintenance by removing free air out of the system
    • No water contamination through the conical shape and long distance between water level and venting valve
    • Reduced noise level thanks to efficient air venting
  • Technical Features

    Design

    Multistage, submersible, rainwater storage tank pump.

     

    Application

    • Designed for pumping drinking water (in accordance with ACS) and rainwater with up to 50 g/m³ sand content from wells and rainwater storage tanks for irrigation, sprinkling and water supply.

     

    Typekey

    Example: TWI5-SE 304 EM-FS
    TWI5 Submersible rainwater storage tank pump
    SE Version with side suction port
    3 Rated volume flow Q in m³/h
    04 Number of stages
    EM Mains connection:
    • EM = Single-phase current
    • DM = Three-phase current
    FS Version with attached float switch

     

    Technical Data

    • Mains connection: 1~230 V, 50 Hz and 3~400 V, 50 Hz
    • Fluid temperature: 5 °C to 35 °C
    • Max. operating pressure: 10 bar
    • Max. sand content: 50 g/m3
    • Max. immersion depth: 20 m
    • Protection class: IP68
    • Connection on the discharge side: Rp 1¼
    • Connection on the suction side (SE version): Rp 1¼

     

    Equipment/function

    • TWI5  EM:
      • For wet installation in tanks and rainwater storage tanks
      • With suction strainer
      • Single-phase current motor with thermal motor protection and 20 m of connection cable
      • Switch box (IP55) with on/off switch, 2 m connection cable and CEE7/7 plug
      • The switch box is ready for connecting a float switch.

       

      TWI5  EM-FS:

      • For wet installation in tanks and rainwater storage tanks
      • With suction strainer and fitted float switch
      • Single-phase current motor with thermal motor protection and 20 m of connection cable
      • Switch box (IP55) with on/off switch, 2 m connection cable and CEE7/7 plug
      • The switch box is ready for connecting a float switch.

       

      TWI5 SE  EM:

      • For wet installation in tanks and rainwater storage tanks and for dry installation outside tanks and rainwater storage tanks
      • With side inlet (SE) for connecting a floating filter
      • With pedestal (including 4 vibration absorbers) for floor installation
      • Single-phase current motor with thermal motor protection and 20 m of connection cable
      • Switch box (IP55) with on/off switch, 2 m connection cable and CEE7/7 plug
      • The switch box is ready for connecting a float switch.

       

      TWI5 SE  EM-FS:

      • For wet installation in tanks and rainwater storage tanks and for dry installation outside tanks and rainwater storage tanks
      • With side inlet (SE) for connecting a floating filter
      • With pedestal (including 4 vibration absorbers) for floor installation
      • With attached float switch
      • Single-phase current motor with thermal motor protection and 20 m of connection cable
      • Switch box (IP55) with on/off switch, 2 m connection cable and CEE7/7 plug
      • The switch box is ready for connecting a float switch.

       

      TWI5  DM:

      • For wet installation in tanks and rainwater storage tanks
      • With suction strainer
      • Three-phase current motor
      • Connection cable with bare cable end

       

      TWI5 SE  DM:

      • For wet installation in tanks and rainwater storage tanks and for dry installation outside tanks and rainwater storage tanks
      • With side inlet (SE) for connecting a floating filter
      • With pedestal (including 4 vibration absorbers) for floor installation
      • Three-phase current motor
      • Connection cable with bare cable end

     

    Materials

    • Housing: 1.4301
    • Impeller: 1.4301
    • Shaft: 1.4301
    • Seal:
      • On the fluid side: SIC/SIC
      • On the motor side: Carbon/ceramic
      • Static: NBR

     

    Construction

    Rainwater storage tank pump in monobloc design with radial impeller as multistage hydraulics.

    Single-phase current motor with sheath flow cooling. The motor is cooled by the pumped fluid. The motor is equipped with automatic thermal motor monitoring.

    The motor itself is dry. Two mechanical seals are used to seal the motor and the fluid. There is an oil separation chamber between the two mechanical seals. The oil separation chamber is filled with white oil and absorbs leakage through the seal on the fluid side.

    Connection cable with fitted plug.

    Accessories

    • Gate valve
    • Non-return valve
    • Float switch
    • Pressure switch
    • Electrodes
    • Switchgears
    • Alarm switchgears
    • Suction filter with floater:
      • Coarse filter
      • Fine filter
  • Downloads

Why Wilo Pumps…

test

Self-Priming

test

Convenient

test

Highly-Efficient

test

Noise-Free

test

Diversity

test

Optimised Design

What Trebles Customers Think

We relied on Trebles expertise to ensure the right products were sourced for our project.

Top workmanship and a professional attitude from a supportive team

Excellent customer service again! You genuinely make my life so much easier

Excellent service and a company I would recommend to anyone in future

Engineers were very professional with an excellent knowledge of their trade

We’re writing to express our sincere thanks to all who help ensure our hospitals are able to run smoothly

Job delivered and commissioned at the height of the pandemic with no changes to the excellent service we always receive.

The team at Trebles were great. I really can’t praise them enough.

Not many providers would be able to fully breakdown & rebuild a booster on site