Wilo-Medana CV1-L

Efficient system integration for drinking water applications.

Enquire About This Product

  • Description

    The non-self-priming, multistage pump Wilo-Medana CV1-L covers basic customer needs and reaches high hydraulic performances. Its compact and robust design with corrosion-resistant components enables the use in drinking water applications. It can be applied in ambient temperatures up to 50°C offering a large field of applications for pump integration into systems.

  • Advantages
    • Suitable for drinking water and for special applications due to stainless steel structure
    • Space-saving, compact and robust pump design
    • Suitable for use in ambient temperatures of up to 50 °C and expanded field of application especially for system integration
  • Technical Features

    Design

    Non-self-priming, multistage high-pressure centrifugal pump in vertical design with in-line connections.

     

    Application

    • Water supply and pressure boosting
    • Industrial recirculation systems
    • Process water
    • Closed cooling circuits
    • Fire-fighting systems
    • Washing systems
    • Irrigation
    • Rainwater utilisation

     

    Equipment/function

    • Pump in in-line design, with a continuous motor pump shaft
    • Hydraulics and pump housing in 1.4301 (AISI 304)
    • Oval flange connection
    • Single-phase or three-phase AC motor
    • Single-phase AC motor equipped with capacitor and built-in thermal motor protection (with automatic restart)

     

    Typekey

    Example: Wilo-Medana CV1-L.602-1/E/A/10O
    Medana Product designation surface pump
    CV Commercial vertical
    1 Series level (1 = entry, 3 = standard, 5 = premium)
    L Long shaft (with a continuous motor pump shaft)
    6 Nominal volume flow [m3/h] of the single pump
    2 Number of single pump stages
    1 1 = AISI 304
      2 = AISI 316L
    E E = EPDM, V= FKM gasket
    A A = frequency 50 Hz/single-phase/230 V
      B = frequency 60 Hz/single-phase/220 V
      C = frequency 60 Hz/single-phase/230 V
      D = frequency 50 Hz/three-phase/400 V
      E = frequency 50 Hz/three-phase/230 – 400 V
      F = frequency 60 Hz/three-phase/220 – 380 V
      G = frequency 60 Hz/three-phase/265 – 460 V
      I = frequency 60 Hz/three-phase/460 V
    10 Rated pressure (bar)
    O O = Oval flange connections
    F = DIN round flange connections
    P = Vicaulic connections

     

    Technical Data

    • Mains connection 1~230 V (±10 %), 50 Hz, with integrated thermal motor protection
    • Mains connection up to 4 kW 3~230 V (±10 %), 50 Hz (Δ), 400 V (±10 %), 50 Hz (Y)
    • Mains connection up to 4 kW 3~265 V (±10 %), 60 Hz (Δ), 460 V (±10 %), 60 Hz (Y)
    • Mains connection up to 4 kW 3~220 V (±10 %), 60 Hz (Δ), 380 V (±10 %), 60 Hz (Y)
    • Mains connection 5.5 kW 3~400 V (±10 %), 50 Hz (Δ), 690 V (±10 %), 50 Hz (Y)
    • Mains connection 5.5 kW 3~460 V (±10 %), 60 Hz (Y)
    • Mains connection 5.5 kW 3~380 V (±10 %), 60 Hz (Δ), 660 V (±10 %), 60 Hz (Y)
    • 3~ pumps can optionally be ordered with motors that are equipped with thermal sensors (PTC). This option could be required for use with external frequency converter.
    • Protection class IP55
    • Fluid temperature of -20 to +120 °C
    • Ambient temperature of -15 to +50 °C (extended temperature ranges on request)
    • Operating pressure max. 10 bar or max. 16 bar, depending on type
    • Max. inlet pressure 6 bar or max. 10 bar depending on type
    • Nominal diameters of pipe connections G1″, G1¼”, G1½” or G2″ depending on type
    • DIN round flange or Victaulic connection available upon request
    • Drinking water approval for pumps with parts in contact with the fluid made of stainless steel (EPDM version)

     

    Materials

    • Impellers 1.4301 (AISI 304) stainless steel
    • Stage chambers 1.4301 (AISI 304) stainless steel
    • Shaft 1.4301 (AISI 304) stainless steel
    • Pump housing 1.4301 (AISI 304) stainless steel
    • Pump impellers, stage chambers, shaft, and pump housing in 1.4404 (AISI316L) stainless steel upon request. Pump housing in 1.4404 (AISI316L) available only with DIN round flange.
    • Pump baseplate EN-GJL-250 (cataphoretic-coated)
    • Gasket EPDM (FKM optionally)
    • Mechanical seal B-carbon/silicon carbide
    • Bearing tungsten carbide/aluminium oxide

     

    Construction

    Non-self-priming vertical multistage pump in in-line design.

  • Downloads

Why Wilo Pumps…

test

Self-Priming

test

Convenient

test

Highly-Efficient

test

Noise-Free

test

Diversity

test

Optimised Design

What Trebles Customers Think

We relied on Trebles expertise to ensure the right products were sourced for our project.

Top workmanship and a professional attitude from a supportive team

Excellent customer service again! You genuinely make my life so much easier

Excellent service and a company I would recommend to anyone in future

Engineers were very professional with an excellent knowledge of their trade

We’re writing to express our sincere thanks to all who help ensure our hospitals are able to run smoothly

Job delivered and commissioned at the height of the pandemic with no changes to the excellent service we always receive.

The team at Trebles were great. I really can’t praise them enough.

Not many providers would be able to fully breakdown & rebuild a booster on site