Wilo-Helix VF (VdS)

Highly efficient high-pressure multistage centrifugal pump in vertical design with in-line connections, VdS certified for use as sprinkler pump in stationary water extinguishing systems.

Enquire About This Product

  • Description

    Highly efficient high-pressure multistage centrifugal pump in vertical design with in-line connections, VdS certified for use as sprinkler pump in stationary water extinguishing systems.

  • Advantages
    • Vds certification as sprinkler pump (above ground) in stationary water extinguishing systems
    • Efficiency-optimised, laser-welded 2D/3D hydraulics
    • Corrosion-resistant impellers, guide vanes and stage housings
    • Flow and degassing-optimised hydraulic parts
    • Reinforced pump housing, flow and NPSH optimised
    • Space-saving and easy maintenance due to the compact design
    • Particularly sturdy coupling guard
  • Technical Features

    Design

    Highly efficient high-pressure multistage centrifugal pump in vertical design with in-line connections, VdS certified for use as sprinkler pump in stationary water extinguishing systems.

     

    Equipment/function

    Use of different pump housing connections is possible which is available on Helix standard pump ranges. The material of pump housing shall have the elongation at break at least 15%.

    Wilo-Helix FIRST pumps are VdS certified up to 110 m delivery head. These pump versions are not allowed to exceed the defined delivery head and the allowable pressure 12 bar. Wilo-Helix FIRST pump housing is made of cast iron GJL250. VdS requires JL1040 or at least equivalent material as sufficient.

    Wilo-Helix VF and Wilo-Helix FIRST VF fulfil the VdS requirement of non – rusting metal with a melting point > 800 °C for pump shafts, shaft protection sleeves, impellers, impeller mounting components and wear rings.

    The connection of pumps and motors shall be made separately by a coupling. The power provided by the motor must be sufficient for the H(Q) curve. Overload values or values for short time operation are not allowed on VdS certified Helix series. The torque of the drive motors shall be greater as the counter torque exerted by the pump all the way from standstill to rated speed. The motor power and overload is found at power peak 5% and at 16m NPSH.

    Qzul means Q zulässig. This is a German description for permissible delivery flow. The duty point must not be at the right of this limit. When delivering at 1.2 times the permissible delivery flow, an NPSHR of 5.5 m shall not be exceeded.

    The formula used for Qzul:

    Q4.5mNPSH times 1.2 must not exceed Q5.5m NPSH, in this case Qzul = Q4.5m NPSH.

    If the result exceed the value of Q5.5m NPSH then Qzul is Q5.5m NPSH/1.2.

     

    Wilo SE must conduct a pressure test with each pump casing in finished condition or in assembled condition. Each Helix VF and Helix FIRST VF is to test in assembled condition:

      • Test medium: water
      • Test pressure: 1.5 times allowable pressure
      • No signs for breaks/ cracks or inadmissible plastic deformation is visible during and after the test

     

    Technical Data

    Basis of VdS approval:

    • VdS 2344:2014-07
    • VdS 2100-07:2013-05

    The VdS approval No. is P 418007

     

    Materials

    • Wilo – Helix VF pump types VdS certified are available in AISI304 and AISI316L. The pumps are available with standard mechanical seal or cartridge mechanical seal. Wilo-Helix VF and Wilo-Helix FIRST VF fulfil the VdS requirements for seal materials such as for example EPDM, FKM.

     

    Construction

    The non self-priming high-pressure multistage centrifugal pump has a particularly compact overall design. The pump shaft and the motor shaft of the IEC standard motor are connected by means of a clamp coupling. A separate lantern roller bearing ensures optimum admission of axial thrusts.

    Intermediate bearings in the hydraulics and corrosion-resistant shaft due to stainless steel sleeve ensure a long service life. Special, permanently attached lifting eyes enable easy pump installation.

    The marking of the pump is non-detachable, non-flammable and permanent.

  • Downloads

Why Wilo Pumps…

test

Self-Priming

test

Convenient

test

Highly-Efficient

test

Noise-Free

test

Diversity

test

Optimised Design

What Trebles Customers Think

We relied on Trebles expertise to ensure the right products were sourced for our project.

Top workmanship and a professional attitude from a supportive team

Excellent customer service again! You genuinely make my life so much easier

Excellent service and a company I would recommend to anyone in future

Engineers were very professional with an excellent knowledge of their trade

We’re writing to express our sincere thanks to all who help ensure our hospitals are able to run smoothly

Job delivered and commissioned at the height of the pandemic with no changes to the excellent service we always receive.

The team at Trebles were great. I really can’t praise them enough.

Not many providers would be able to fully breakdown & rebuild a booster on site