Wilo-EMU FA (customised)

Submersible sewage pump with and without active cooling system for continuous duty in the stationary and portable wet well installation, as well as for stationary dry well installation.

Enquire About This Product

  • Description

    Submersible sewage pump with and without active cooling system for continuous duty in the stationary and portable wet well installation, as well as for stationary dry well installation.

  • Advantages
    • Can be tailored to suit your exact requirements. For reliable and efficient pumping of pre-treated sewage and untreated sewage.
    • Versatile. Optimum pumping of various fluids at all times using different impeller shapes.
    • Energy-efficient thanks to optional IE3 motor technology
    • Protected against abrasion and corrosion with Ceram coating and special materials
    • Suitable for immersed and non-immersed applications, even in continuous duty
  • Technical Features

    Design

    Submersible sewage pump with and without active cooling system for continuous duty in the stationary and portable wet well installation, as well as for stationary dry well installation.

     

    Application

    Pumping of:

    • Untreated sewage with faeces and long-fibre components
    • Sewage containing faeces
    • Pre-cleaned sewage without faeces and long-fibre components
    • Process water
    • Wastewater

     

    Equipment/function
    • Heavy-duty version made of grey cast iron
    • Surface-cooled motor or self-cooling motor with 1-chamber or 2-chamber system
    • Optionally with Ex protection in accordance with ATEX or FM
    • Motor-dependent monitoring devices:
      • Winding temperature
      • Moisture monitoring in the sealing chamber and motor/terminal room
      • Motor bearing temperature
    • Installed accessories according to customer requirements

     

    Typekey
    Example: Wilo-EMU FA 20.54E + FK 17.1-6/16KEx
    Hydraulics: FA 20.54E
    FA Submersible sewage pump
    20 x10 = nominal diameter discharge port, e.g. DN 200
    54 Performance indicator
    E Type of impeller:

    W = Vortex impeller

    E = Single-channel impeller

    Z = Two-channel impeller

    D = Three-channel impeller

    V = Four-channel impeller

    Motor: FK 17.1-6/16KEx
    FK Motor type:

    T = surface-cooled motor without cooling system

    FK, FKT, HC = self-cooling motor with active cooling system

    17.1 Size
    6 Number of poles
    16 x10 = package length in mm
    K Seal version:

    H = rotary shaft seal/mechanical seal

    G = two separate mechanical seals

    K = block seal cartridge with two mechanical seals

    Ex Ex-rated

     

    Technical Data

    • Mains connection: 3~400 V, 50 Hz
    • Submerged operating mode: S1
    • Non-immersed operating mode: S1 or S2
    • Protection class: IP68
    • Insulation class: H
    • Fluid temperature: 3…40 °C, higher temperatures on request
    • Free ball passage of 45…130 mm
    • Max. immersion depth: 20 m

     

    Materials
    • Housing components: EN-GJL or EN-GJS
    • Impeller: EN-GJL or EN-GJS
    • Static gaskets: NBR or FPM
    • Fluid-side seal: Mechanical seal made of SiC/SiC
    • Seal on the motor side:
      • Rotary shaft seal NBR
      • Mechanical seal made of SiC/SiC or carbon ceramic
    • Shaft: Stainless steel 1.4021

     

    Construction

    Submersible sewage pump as submersible monobloc unit for stationary and portable wet well and dry well installation.

    Hydraulics

    The outlet on the pressure side is designed as horizontal flange connection. The maximum possible dry matter content is 8 %, depending on the hydraulics and impeller type. The following impeller shapes are used:

    • Vortex impeller (W)
    • Single-channel impeller (E)
    • Two-channel impeller (Z)
    • Three-channel impeller (D)
    • Four-channel impeller (V)

    The sewer hydraulics are equipped with an impeller wear ring and casing wear ring made of hardened material. These contribute long-term to ensuring the uniform efficiency of the unit and minimizing maintenance costs.

    Motor

    Surface-cooled motors (T motor) do not have a cooling system of their own and emit their heat directly to the surrounding fluid via the housing parts. The motors can therefore be used in immersed state for continuous duty. Depending on their size, they can also be used in non-immersed state for short-time duty.

    The self-cooling motors (FK, FKT, HC motors) have an active cooling system and transfer their waste heat to the medium being pumped by means of an integrated heat exchanger. Therefore, these motors are suitable for continuous duty in immersed and non-immersed condition, and therefore also for dry well installation.

    All motors have a sealing chamber that protects the motor from fluid ingress. It can be accessed from the outside and can optionally be monitored with a rod electrode. All filling fluids used are potentially biodegradable and environmentally safe.

    The connection cable has bare cable ends and a length of 10 m or a customer-specific length. The cable inlet on T, HC and FKT motors is longitudinally watertight.

    Seal

    Fluid-side and motor-side sealing is possible in the following versions depending on the motor type:

    • Version H: Mechanical seal for the fluid side, rotary shaft seal for the motor side
    • Version G: Two independently-acting mechanical seals
    • Version K: Block seal cartridge with two independently acting mechanical seals

    High efficiency motors

    In addition to the standard motors, high-efficiency motors with IE3 classification (in accordance with IEC 60034-30) are also available. As these have the same basis as the standard motors, they have the same features and functions. This means that the same hydraulic systems are also available.

    Ex rating

    The motors are available with Ex rating in accordance with ATEX and FM.

     

    Accessories

    • Suspension unit or pump support foot
    • Various pressure outlets and Storz couplings
    • Chains
    • Fixation sets with anchor bolts
    • Switchgear, relays and plugs
    Options
    • Special voltages
    • Winding monitoring with PTC thermistor sensor
    • Monitoring devices for
      • Sealing chamber
      • Motor/terminal room
      • Storage temperature
    • Ceram coating for abrasive and corrosive fluids
    • Ex-rated according to ATEX or FM
  • Downloads

Why Wilo Pumps…

test

Self-Priming

test

Convenient

test

Highly-Efficient

test

Noise-Free

test

Diversity

test

Optimised Design

What Trebles Customers Think

We relied on Trebles expertise to ensure the right products were sourced for our project.

Top workmanship and a professional attitude from a supportive team

Excellent customer service again! You genuinely make my life so much easier

Excellent service and a company I would recommend to anyone in future

Engineers were very professional with an excellent knowledge of their trade

We’re writing to express our sincere thanks to all who help ensure our hospitals are able to run smoothly

Job delivered and commissioned at the height of the pandemic with no changes to the excellent service we always receive.

The team at Trebles were great. I really can’t praise them enough.

Not many providers would be able to fully breakdown & rebuild a booster on site