Description
Execution
Energy saving variable speed circulating pump driven by a permanent magnet synchronous motor (pm) controlled by on board inverter.
Bronze pump casing.Applications
Sanitary hot water systems.
Operating conditions
Liquid temperature from +5 °C to +65 °C
– Ambient temperature from 0 °C to +40 °C
Maximum permissible working pressure: 3 bar
Storage: -10°C/+50°C max. relative humidity 95% at 40 °C
– Certifications: in conformity with CE requirements
Sound pressure ≤ 45 dB (A).
– Minimum suction pressure: – 0,05 bar at 75 °C 0,28 bar a 90 °C.
EMC secondo: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3.
Connections: threaded ports ISO 228: G 1. -
Technical Features
Technical data
FLOW
0.2 / 2.6
mc / hHEAD
0.4 / 6
mPOWER
0.01 / 0.045
kW - Downloads