Wilo-Sevio ELASTOX-D 12

Aeration system consisting of disc diffuser and pipeline system to distribute compressed air.

Enquire About This Product

  • Description

    Aeration system consisting of disc diffuser and pipeline system to distribute compressed air. On-site downspout or air intake pipe can be connected directly to pipeline system.

  • Advantages
    • Increased operational reliability thanks to spring-loaded hoist restriction of the plate diffuser to evenly expand the membrane for ideal air intake. Thanks to its special design, the air intake is sealed when the membrane is not loaded to prevent fluid penetrating the pipeline system
    • Ideal adaptation of the air intake thanks to three different perforation patterns
    • Greatest possible process-specific activation density by taking different basin geometries and installation conditions into account
    • High flexibility in the system control through very wide control range of the air intake
    • High quality and service life of the membranes thanks to the production of moulded products
  • Technical Features

    Design

    Aeration system consisting of disc diffuser and pipeline system to distribute compressed air. On-site downspout or air intake pipe can be connected directly to pipeline system.

     

    Application

    • For fine bubble aeration of various fluids such as wastewater and sewage or sludge, for the purpose of supplying oxygen and mixing.

       

    Equipment/function

    Compressed air generators input air into the pipeline system via the air intake pipe. The pipeline system evenly distributes the supplied air to individual diffusers. Air is evenly input to the fluid free from coalescence via a sewage-resistant membrane.

    Technical Data

    • Nominal diameter 320 mm
    • Perforation area 650 cm2
    • Max. weight 0.95 kg
    • Air load, min.
      • 1.2 Nm³/h (Type B)
      • 1.5 Nm³/h (Type C)
    • Air load, nominal
      • 6.0 Nm³/h (Type B)
      • 10 Nm³/h (Type C)
    • Air load, max.
      • 8.0 Nm³/h (Type B)
      • 12 Nm³/h (Type C)
    • Air load, max. (for short periods)
      • 12 Nm³/h (Type B)
      • 16 Nm³/h (Type C)
    • Air intake min. temperature 5 °C
    • Air intake max. temperature 80 °C (optionally up to 120 °C)
    • Min. fluid temperature 5 °C
    • Max. fluid temperature 35 °C

     

    Materials
    • Membrane
      • EPDM, microbe-resistant EPDM or silicone

       

      Membrane attachment

      • VA

       

      Support element

      • PP

       

      Pipe system

      • Square pipe: Stainless steel
      • Round pipe: Stainless steel or plastic
      • Fixation: Stainless steel and plastic
      • Gasket: Flat gasket made of NBR

     

    Construction

    The aeration system is composed of one or more aeration fields. An aeration field consists of several components.

    The disc diffuser consists of a supporting plate featuring threaded connection, a plate membrane with hoist restriction and a fastening clip. Thanks to the spring-loaded hoist restriction the membrane expands evenly, thus guaranteeing ideal air intake.

    When the membrane is not loaded, the special design makes sure the air intake is sealed. This prevents fluids entering the pipeline system. As a result of the membrane’s excellent resilience, its perforation remains sealed when the membrane is not loaded.

    As standard, disc diffusers are installed on the pipeline system using a threaded nipple on the square pipe or a saddle clamp on the round pipe.

    The energy-efficient pipeline system guarantees ideal air distribution with low levels of pressure loss. It is detachable, height-adjustable and adapted to the characteristics of the basin and other plant technology.

     

    Option
    • Dosing facility for cleaning and regenerating diffusers by dosing air volume flow with appropriate chemicals. Consists of:
      • Dosing tank
      • Dosing pump
      • Connection accessories
      • Trolley for mobile version option
    • Test lance for checking diffusers during operation. Detachable design for configuration with at least two diffusers. Designed to enable extraction from the basin without reducing the water level or interrupting operation. Consists of:
      • Lifting device made of stainless steel
      • Rope winch in weather-resistant version
      • Wire rope made of stainless steel
      • Required guidance devices made of stainless steel, complete fixing equipment
    • Downspout
    • Drainage pipe
    • Temperature resistance up to 120 °C
      • Disc diffuser
      • O-ring made of FKM
      • Flat gasket made of EPDM
    • Additional monitoring systems on request
  • Downloads

Why Wilo Pumps…

test

Self-Priming

test

Convenient

test

Highly-Efficient

test

Noise-Free

test

Diversity

test

Optimised Design

What Trebles Customers Think

We relied on Trebles expertise to ensure the right products were sourced for our project.

Top workmanship and a professional attitude from a supportive team

Excellent customer service again! You genuinely make my life so much easier

Excellent service and a company I would recommend to anyone in future

Engineers were very professional with an excellent knowledge of their trade

We’re writing to express our sincere thanks to all who help ensure our hospitals are able to run smoothly

Job delivered and commissioned at the height of the pandemic with no changes to the excellent service we always receive.

The team at Trebles were great. I really can’t praise them enough.

Not many providers would be able to fully breakdown & rebuild a booster on site