Wilo-BAC

The OEM safe solution for Chillers and Heat-Pumps.

Enquire About This Product

  • Description

    The Wilo-BAC series is specifically designed for safe integration into Chillers & Heat Pumps, including new generations using the eco-friendly R290 refrigerant. For that purpose, the BAC50 was tested by an external laboratory to verify compliance with the requirements of clauses 22.116 and 22.117 of IEC 60335-2-40:2022.

    Its Victaulic ports make the connection quick and easy. It is available in different power rates with high interchangeability, providing a high flexibility of usage. Designed specifically for continuous operation, the pump also offers a long service life thanks to its corrosion-resistant materials or coatings and maintenance-free roller bearings.

  • Advantages
    • Highest level of safety in heat pumps and chillers due to compatibility with refrigerants up to R290 gas
    • Energy savings thanks to ultra-modern hydraulics and motors​
    • Victaulic connection for quick installation​
    • Optimised pump dimensions for flexibility during replacement​
    • High reliability thanks to top-quality mechanical seal and bearing
    • Low noise due to modern motor design​​
    • optional: Maximum comfort with electrical connection thanks to quick connection plug
  • Technical Features

    Design

    Glanded pump in monobloc design with Victaulic connection.

     

    Application
    • For pumping cooling and cold water, water-glycol mixtures and other fluids without abrasive substances.
    • The BAC50 can be used in R290 heat pumps (in accordance with IEC 60335-2-40).

     

    Typekey

    Example BAC 50/122-1.5/2
    BAC Monobloc pump for cooling and air-conditioning applications
    50 Pipe connection (pressure port)
    122 Impeller diameter
    1.5 Rated motor power P2 in kW
    2 Number of poles

     

    Technical data

      • Permissible temperature range: -15 °C to +60 °C (BAC70)
      • Permissible temperature range: -15 °C to +90 °C (BAC50)
      • Mains connection 3~400 V, 50 Hz (others on request)
      • Protection class IP55
      • Victaulic connection: DN 50 (60.3 mm) or DN 65 (76.1 mm)
      • Max. operating pressure 10 bar (BAC50) or 6.5 bar (BAC70)

     

    Equipment/function

    Single-stage low-pressure centrifugal pump in block design, with axial suction port and radially arranged pressure port

     

    Materials

    • Pump housing: PA 6.6 50 % GF (BAC70)
    • Pump housing: EN-GJL-250 (BAC50)
    • Impeller: PA/PPO, fibreglass-reinforced
    • Shaft: X30Cr13
    • Mechanical seal: BQEGG

     

    Construction

    • Single-stage low-pressure centrifugal pump in block design, with axial suction port and radially arranged pressure port.
  • Downloads

Why Wilo Pumps…

test

Self-Priming

test

Convenient

test

Highly-Efficient

test

Noise-Free

test

Diversity

test

Optimised Design

What Trebles Customers Think

We relied on Trebles expertise to ensure the right products were sourced for our project.

Top workmanship and a professional attitude from a supportive team

Excellent customer service again! You genuinely make my life so much easier

Excellent service and a company I would recommend to anyone in future

Engineers were very professional with an excellent knowledge of their trade

We’re writing to express our sincere thanks to all who help ensure our hospitals are able to run smoothly

Job delivered and commissioned at the height of the pandemic with no changes to the excellent service we always receive.

The team at Trebles were great. I really can’t praise them enough.

Not many providers would be able to fully breakdown & rebuild a booster on site